Virtual assistant
Installer
Getting Started Guide
Solutions and documentation structure
Equipment ordering and commissioning
General terms and conditions of sale and warranty
Wiring diagrams
Gateway and communication
Community - Electricity Metering - RCP
Heating - Heating metering and water
Mobility - EV Charging Stations
Washaccess - Collective laundry manager
EBike - Recharge electric bikes
Self-consumption optimization
Building energy monitoring
Equipment and installation
Configuration and commissioning
Commissioning
Getting Started Guide
Add a router to a site
Add a Climkit Gateway to a site
Electricity meter configuration
Charging station configuration
Configuration of heating and water meters (MBus)
Installation of Shelly relay meters
Optimization via EV relays and charging stations
Checking meter connection status
Advanced configuration
Configuration Gateway
RFID reader and relay meter configuration
IP network configuration and routers
RS485-Ethernet TCP/IP Converters
Configure Teltonika RUT241
Display configuration
Modbus Meter Configuration
Metering data processing
Manually read meter
Inepro PRO380 Meters and various
ABB Terra AC Charging Station Configuration
Wallbox configuration
Firewall rules for Climkit Gateway
Schneider EVlink Pro AC Charging Station Configuration
Zaptec Charging Station Configuration
Owner
Administrative setup
Getting started guide - administrative setup
Form - 1. Contact details
Form - 2. Solutions
Form - 3. Rates
Contract and documents to complete
Owner account
Consumer information flyers
Online access, RFID badge and charging stations
FAQ and other information
Resident
Platform
Platform access
Terminology
Site
Parameters
Creation/edit of a note or to-do item
Closing an open issue
Site statuses
Add/Modify building(s)
The steps for setting up a site
Delete/deactivate a site
Add/Edit Equipment(s)
Modify site basic information
Equipment
Add/modify a gateway
Add/modify a router
Add/modify an electricity meter
Bulk meter insertion
Mass assigning meters to a gateway
Add/edit a distribution zone
Add/modify a charging station
Add/modify a thermal or water meter
Add/edit a DSO meter (FTP transfer)
Remote connection to a Climkit gateway
Administration
Stakeholders
Financial conditions
Visualizing Site Management Conditions
Activating/Deactivating a Solution
Configuration of the Operating Method
Visualizing Financial Conditions
Creation/editing/addition of a financial condition
Removal of a financial condition
Accounts
Create a consumer account
Create a contact
View and download account invoices
Send platform access to a contact
Add/modify billing address
Link an existing account to a site
Changing the correspondence method
Rates and billing points
Creating/editing a billing point
Register a move (relocation)
Account assignment to a billing point
Add/edit default charge advance payment for a billing point
View site consumption rates
Consumption Rate Edition
Creation/editing of a consumption tariff
Creation/editing of a Tariff component
View fixed rates and subscriptions
Customize invoice position labels/titles
View Financial conditions billed at billing points
RFID badges
Accounting
Tools
Meter control
Visualization
Expense accounts
Introduction to the Expense Statement Tool
Create/edit an expense accounting period
Modify expense statement settings
Add/edit a overhead expense invoice on an expense statement
Edit collected advance payments of an expense statement
Specifics of heating and hot water production costs
Check and download meter readings for the cost accounting period
Allocate expenses and generate expense statements
Exporting individual consumptions for the billing period
API
Table of Contents
- Categories
- Installer
- Equipment and installation
- Metering infrastructure
- Heating and water meters
Heating and water meters
1. Thermal and water meters
Thermal meters and water meters are installed directly on a pipe.
A water meter measures the flow rate (m³) circulating in the pipe.
A thermal meter measures the flow rate as well as the inlet and outlet temperatures of the circuit, which it then converts into energy (kWh).
The nominal size of a meter (DN) is determined by its measuring chamber and not by its connection section.
Ex. A DN20 meter has a 1" thread on the meter, which means that the fitting screwed onto it for the pipe is 3/4".

Meters of the same DN also have the same length.
Comparative table of DN sizes
Nominal size | Meter thread | Length | Flow rate | Screwed connection thread |
DN 15 | 3/4" | 110 mm | 2.5 m³/h | 1/2" |
DN 20 | 1" | 130 mm | 4 m³/h | 3/4" |
DN 25 | 1 1/4" | 260 mm | 6.3 m³/h | 1" |
DN 32 | 1 1/2" | 260 mm | 10 m³/h | 1 1/4" |
DN 40 | 2" | 300 mm | 16 m³/h | 1 1/2" |
DN 50 | 2 1/2" | 300 mm | 25 m³/h | 2" |
To communicate with the Climkit Gateway, all meters must be equipped with a wired MBus communication module.
Here are some examples of standard heating and water meters:
2. Thermal meters for heat or cooling
Integra Amtron S3U Meter
- Ultrasonic (heat and cooling) battery-powered (10-year lifespan)
- No wear or other issues like with mechanical versions.
- Primarily used for apartments.
- Usually used in DN15 or DN20. Also available in DN25.

Models for heat (DN15 and DN20)
- AMTRON S3U_15_1.5_110_G3/4_BM_h – 97154
- AMTRON S3U_20_2.5_130_G1_BM_h - 97155
Models for heat and cooling (DN15 and DN20)
These meters have two indices (kWh heat and kWh cold).
They increment respectively if the temperature difference between the two probes is positive or negative.
- AMTRON S3U_15_1.5_110_G3/4_BM_hc – 97174
- AMTRON S3U_20_2.5_130_G1_BM_hc - 97175
Models for cooling (DN15 and DN20)
- AMTRON S3U_15_1.5_110_G3/4_BM_c – 97190
- AMTRON S3U_20_2.5_130_G1_BM_c - 97191
DN25 or larger
For DN32 or larger, use the Sonic D.
The Sonic D is powered by 230V (no battery).
Generally used for measurements at the boiler outlet, in CAD substations, and for domestic hot water production.

3. Hot water (DHW) or cold water (CW) meters
DHW and CW meters are the same.
Surface-mounted water meter (DN15 and DN20)
- SAPHIR Modularis ETW 15 1.5_110_G3/4 BM – 95148
- SAPHIR Modularis ETW 20 2.5_130_G1 BM – 95149

Coaxial water meter for flush mounting
- SAPHIR Modularis MTW IE koax 1.5 BM – 95142

Available accessories: extension piece (if too far from the wall) and decorative escutcheon

Example of mounting system for flush-mounted meter:

Datasheet: Saphir Modularis meter
Mounting Guide: Saphir Modularis surface-mounted
Mounting Guide: Saphir Modularis Koax flush-mounted
Water meter DN25 or larger
For DN25 or larger, use the PMK-aquabasic
Ideal for high flow rates such as irrigation.
Note: 3 types depending on mounting:
- Horizontal
- Vertical descending
- Vertical ascending
Supplied with screwed connection kit and MBus communication module.

4. MBus Converter