Contractor
Getting started
Solutions and documentation structure
Material ordering and commissioning
General Sales Terms and Conditions and Warranty
Connection diagrams
Gateway et communication
Community - Electricity metering - RCP
Heating - Heating and water metering
Mobility - Charging stations for electric vehicles
Washaccess - Laundry Manager
EBike - Electric bike charging
Optimization of self-consumption
Energy monitoring of the building
Equipment and installation
Gateway Climkit
4G router
LAN router
RS485-Ethernet converter
Switch ethernet DIN POE
WiFi network
Electric meters
MBus-RS485 converter
Heating & Water Meters
EV Charging Stations
I/O module 4 relays 8 DI
RFID Readers
Relay meters
Commissioning
Configuration and commissioning
Getting started guide to commissioning
Add a router to a site
Add a Gateway Climkit to a site
Electric meter configuration
Configuring charging stations
Configuring heating and water meters (MBus)
Optimization via Relays and EV Terminals
Verification of Meter Connections
Advanced Configuration
Configuration Gateway
Cloud Gateway Configuration (MQTT)
RFID Reader Configuration
IP Network Configuration & Routers
RS485-Ethernet TCP/IP converters
Configuring Teltonika RUT241
Configuring Display Screens
Configuring Modbus counters
Processing of Count Data
Meter Read Manually
Inepro PRO380 meters and others
Configuration EV charger Zaptec
Configuration of ABB charging station
Configuration of Schneider EVlink Pro AC charging station
Property Owner
Administrative Setup
Getting Started – Administrative Setup
Form - 1. Contact Details
Form - 2. Solutions
Form - 3. Prices
Contract & Documents to Complete
Online Account for Owners
Information Flyers for Residents
Online Access, RFID Badge & Charging Stations
FAQ & other Information
Resident
Platform
Access to the platform
Site
Parameters
Creation/Editing of a Note or Issue to Address
Close an issue to be addressed
Add/Edit Building(s)
Add/Edit Equipment(s)
Edit Basic Site Information
Administration
Accounts
Create a contact
View and Download Invoices from an Account
Send access to the platform to a contact
Add/Modify Billing Address
Changing the Matching Method
Rates and Billing Points
Creation/editing of a billing point
Registering a move (transfer)
Account Assignment to a Billing Point
Creation/Editing of a Consumption Rate
Add/Modify the Default Charge Deposit of a Billing Point
Creation/Editing of a Consumption Rate Component
Editing a consumption tariff
RFID Badges
Accounting
Tools
Visualization
Expense Reports
Introduction to the Expense Count Tool
Add/Edit a General Expense Invoice from an Expense Statement
Edit the received deposits of an expense statement
Particularities of Heating and Hot Water Production Costs
Check and download meter readings for the billing period.
Distributing and Generating Fee Summaries
Export Individual Consumption for the Expense Reporting Period
API
Table of Contents
- Categories
- Contractor
- Equipment and installation
- Heating & Water Meters
Heating & Water Meters
1. Thermal and water meters
Thermal meters and water meters are installed directly on a pipe.
A water meter measures the flow (m3) circulating in the pipe.
A heat meter measures the flow rate as well as the inlet temperature and outlet temperature of the circuit, which it then converts into energy (kWh).
The caliber of a meter (DN) is determined by its measuring chamber and not by its connection section.
Ex. A DN20 meter has a thread on the meter of 1", which means that the fitting that is screwed onto it for the pipe is 3/4".
Counters of the same DN also have the same length.
Comparative table of DNs
Caliber | Counter thread | Length | Speed | Screw connection thread |
DN 15 | 3/4" | 110mm | 2.5 m3/h | 1/2" |
DN 20 | 1" | 130mm | 4 m3/h | 3/4" |
DN25 | 1 1/4" | 260mm | 6.3 m3/h | 1" |
DN 32 | 1 1/2" | 260mm | 10 m3/h | 1 1/4" |
DN 40 | 2" | 300mm | 16 m3/h | 1 1/2" |
DN 50 | 2 1/2" | 300mm | 25 m3/h | 2" |
In order to communicate with the Gateway Climkit, all meters must be equipped with a wired MBus communication module.
Climkit also provides meters. See standard models below. For special orders, write directly to info@climkit.io .
2. Thermal meters for heat or cold
Integra Amtron S3U meter
- Ultrasonic (hot and cold) battery operated (lifespan of 10 years)
- No wear or other problems like with mechanical versions.
- Used for apartments mainly.
- Normally used in DN15 or DN20. Also available in DN25.
Heat models (DN15 and DN20)
- AMTRON S3U_15_1.5_110_G3/4_BM_h – 97154
- AMTRON S3U_20_2.5_130_G1_BM_h - 97155
Models for heat and cold (DN15 and DN20)
These meters have two indices (hot kWh and cold kWh).
They increment respectively depending on whether the temperature difference between the two probes is positive or negative.
- AMTRON S3U_15_1.5_110_G3/4_BM_hc – 97174
- AMTRON S3U_20_2.5_130_G1_BM_hc - 97175
Cold models (DN15 and DN20)
- AMTRON S3U_15_1.5_110_G3/4_BM_c – 97190
- AMTRON S3U_20_2.5_130_G1_BM_c - 97191
DN25 or higher
For DN32 or higher, take Sonic D.
The Sonic D is powered by 230V (without battery).
Generally used for boiler outlet measurement, in CAD substations and for DHW production.
Precise model to be discussed when ordering.
3. Hot (DHW) or cold (EF) water meters
The DHW and EF counters are the same.
Surface-mounted water meter (DN15 and DN20)
- SAPPHIRE Modularis ETW 15 1.5_110_G3/4 BM – 95148
- SAPPHIRE Modularis ETW 20 2.5_130_G1 BM – 95149
Koax water meter for flush mounting
- SAPPHIRE Modularis MTW IE koax 1.5 BM – 95142
Accessories available: extension (if too far from the wall) and trim rosette
Example of mounting system for flush-mounted meter:
Datasheet: Saphir Modularis
Installation Guide: Saphir Modularis
Installation Guide: Saphir Modularis Koax
Water meter DN25 or higher
For DN25 or higher, take PMK-aquabasic
Ideal for large flow rates such as watering.
Please note 3 types depending on assembly:
- Horizontal
- Vertical descending
- Vertical ascending
Delivered with screw connection kit and MBus communication module.
4. MBus Converter