Add/edit a Distribution system operator (DSO) meter (FTP transfer)

Nicolas Vodoz Updated by Nicolas Vodoz

  1. Create a gateway type FTP
    1. In the "Folder Name" field, specify the name of the "ftp-..." folder of the Distribution system operator (DSO) based on the table in the article Integration of a Distribution system operator (DSO) meter.
    2. Reading frequency: Daily
  2. Create a meter associated with the FTP gateway with the following parameters:
    1. Protocol: FTP
    2. Type: grd_meter
    3. Additional model-related parameters:
      1. foreign_key
      2. if only one POD per meter: insert the POD number: CH101110123450000000000000XXXXXXX
      3. if two PODs per meter (e.g. one for captured energy en_im and the other for surplus en_ex): {'en_im': 'CH101110123450000000000000XXXXXXX', 'en_ex': 'CH101110123450000000000000YYYYYYY'}
  3. Important: If the input meter or production meter of the Distribution system operator (DSO) will be the meter used for measurement, then the corresponding physical Climkit meter in the metering scheme should be ignored. Otherwise, it will distort the data.
    1. If the purpose is to receive Distribution system operator (DSO) data to monitor the Climkit meter, then the Distribution system operator (DSO) meter must be ignored in the metering scheme.

How Did We Do?

Add/modify a thermal or water meter

Connecting remotely to a Climkit gateway

Contact