Add/edit a Distribution system operator (DSO) meter (FTP transfer)

Nicolas Vodoz Updated by Nicolas Vodoz

  1. Create a gateway type FTP
    1. In the "Folder Name" field, specify the folder name "ftp-..." of the DSO based on the table in the article DSO meter integration.
    2. Reading frequency: Daily
  2. Create a meter associated with the FTP gateway with the parameters:
    1. Protocol: FTP
    2. Type: grd_meter
    3. Additional model-related parameters:
      1. foreign_key
      2. if only one POD per meter: insert the POD number: CH101110123450000000000000XXXXXXX
      3. if two PODs per meter (e.g. one for imported energy en_im and the other for exported energy en_ex): {'en_im': 'CH101110123450000000000000XXXXXXX', 'en_ex': 'CH101110123450000000000000YYYYYYY'}
  3. Important: If the DSO input meter or production meter is to be the meter used for measurement, then the corresponding physical Climkit meter should be ignored in the validation scheme. Otherwise, this will distort the data.
    1. If the purpose is to receive DSO data to check the Climkit meter, then the DSO meter should be ignored in the validation scheme.

How Did We Do?

Add/modify a thermal meter or water meter

Connect remotely to a Climkit gateway